Viessmann Boiler: No hot water
No hot water on a Viessmann boiler: DHW is off because the system is off, settings are wrong, or fuel or a fault is the cause.
Applies to: Vitotronic 200 and 300-K
Common causes of no hot water
- Heating system switched off.
- Fuse or MCB tripped.
- DHW heating disabled or DHW temperature/time program wrong.
- No fuel.
- Fault active.
How to fix no hot water: step by step
- Set ON/OFF switches at all control units to ON.
- Turn on the mains isolator if installed and check the fuse/MCB.
- On the 300-K, make sure DHW heating is enabled and check DHW temperature, time and time program.
- Check remote control settings if fitted.
- Check the fuel supply (see fuel guidance on p. 43).
- If a fault shows, scan and note the code, acknowledge it, and notify the contractor.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
Vitotronic 200
HO1BKW2Vitotronic 200, type H01BVitotronic 200, Type HO1B
Vitotronic 300-K
MW1SVitotronic 300-K, type MW2B
Source: Vitotronic 200 and 300-K Operating Instructions, p. 37. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.