Viessmann Boiler: Mount the Vitotronic 300-K control unit
Mount the Vitotronic 300-K control unit on a Viessmann boiler: The control mounts on a metal backplate, with a mid plate and connection enclosure between the backplate and the control rear section.
Applies to: Vitotronic 300-K
How to fix mount the vitotronic 300-k control unit: step by step
- Fasten the metal backplate to the mounting surface with four fasteners.
- Position the mid plate between the backplate and the connection enclosure.
- Install the mid plate and connection enclosure onto the backplate.
- Fasten the connection enclosure and mid plate to the backplate with two fasteners.
- Install the control rear section onto the connection enclosure housing, hook it onto the backplate tabs, and pivot it downwards.
- Fasten the control rear section to the connection enclosure with two fasteners.
If the unit shows an error code, look it up: Viessmann Boiler codes
Models
MW1SVitotronic 300-K, type MW2B
Source: Vitotronic 200 and 300-K installation and service instructions, p. 15. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.