Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Boiler: Immersion sensor installation in a well

Updated · by Aurora Star Tech Inc.

Immersion sensor installation in a well on a Viessmann boiler: Immersion sensors (KF H / SPF F) are not polarity sensitive. Use them in DHW tank or boiler wells. Smaller wells take only one sensor.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Immersion sensors KF H / SPF F

How to fix immersion sensor installation in a well: step by step

  1. Wire the sensor to the 2-pole plug.
  2. Bend the holding tab back if the well size requires it.
  3. Push the sensor fully to the end of the well. In larger DHW wells, keep the spring piece on the side, not in the middle.
  4. Push the wire into the strain relief.
  5. Secure the sensor with the clip, screw or method the well maker specifies.
  6. Plug the sensor into the control socket for its function.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Versatronik 200 installation manual, p. 13. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency Boiler Repair

647-657-2977