Viessmann Boiler: Burner does not switch off at the correct time
Burner does not switch off at the correct time on a Viessmann boiler: Burner keeps running past the programmed heating time.
Applies to: Versatronik 200 heat generator control
Common causes of burner does not switch off at the correct time
- Operating mode or heating program does not match the schedule.
- Minimum boiler temperature setting holds the burner on.
How to fix burner does not switch off at the correct time: step by step
- Check the operating mode is Standard F (test B).
- Check the time and heating program (heating time).
- Check the pump switching mode as for pumps that do not switch off.
- Check the minimum boiler temperature and the type of minimum limiter (corrosion protection).
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Versatronik 200 installation and operating manual, p. 167. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.