Rinnai IP090S Solo Boiler, 90K BTU
The Rinnai boiler, model IP090S, offers a robust heating capacity of 90K BTU, making it suitable for medium-sized homes. This unit operates on natural gas or propane and features electronic ignition for reliable performance. With its compact design—11.5 inches in depth and 18.5 inches in width—it provides efficient heating while conserving space. It's a solid choice for those seeking dependable warmth in their living spaces.

The Solo Boiler CH 90K BTU, IP090S (model IP090S), 90K BTU, is a Rinnai boiler that Aurora Star Tech supplies and installs for homes and businesses across the Greater Toronto Area. Below are the manufacturer specifications we use when sizing and installing this unit.
Key specifications
- Country of Origin: Japan
- UPC: 766156017247
- Unit Type: Heat Only
- Fuel Type: Natural Gas or Propane
- Heating Capacity: 90000 Btu/h
- Input Heating Capacity: 90 MBH
- Input Capacity (DHW): 90000 Btu/h
- Ignition Type: Electronic Ignition
- Vent Type: Concentric
- Flow Rate: 3 GPM
- Efficiency: 95%
- Energy Star: Yes
- Gas Supply Pressure (Max): 13.5 in. w.c.
- Max Working Pressure: 150 PSI
- Supply Voltage: 115V
- Phase: Single Phase
- Hertz: 60Hz
- Gas Connection: 3/4"
Additional features
- Brand: Rinnai
- Product Family: Solo Boiler (Heat-Only Model)
- Model: CH 90K BTU (IP090S)
- Fuel Type: Natural Gas or Liquid Propane Gas (LP) – Convertible with appropriate kit
- Gas Supply Pressure:
- – Natural Gas: Minimum 3.5 in. W.C. (0.87 kPa), Maximum 10.5 in. W.C. (2.61 kPa)
- – Propane Gas: Minimum 8.0 in. W.C. (1.99 kPa), Maximum 13.5 in. W.C. (3.36 kPa)
- Gas Consumption Range: 15,000 Btu/hr minimum to 90,000 Btu/hr maximum
- Installation: Certified for installation in manufactured homes
- Safety Features: Equipped with automatic ignition system
- no pilot light required
- Control Interface: PC Board with digital display for parameter settings and operation mode
Aurora Star Tech handles the job from the site visit and sizing through supply, installation and start-up testing, so you deal with one local team from quote to commissioning.
Not sure if the Rinnai boiler is the right size for your home or building? Request a quote and our team will confirm the sizing, the electrical requirements and the installation details with you before anything is ordered.
| Brand | Rinnai |
| Country of Origin | Japan |
| UPC | 766156017247 |
| Unit Type | Heat Only |
| Fuel Type | Natural Gas or Propane |
| Heating Capacity | 90000 Btu/h |
| Input Heating Capacity | 90 MBH |
| Input Capacity (DHW) | 90000 Btu/h |
| Ignition Type | Electronic Ignition |
| Vent Type | Concentric |
| Flow Rate | 3 GPM |
| Efficiency | 95% |
| Energy Star | Yes |
| Gas Supply Pressure (Max) | 13.5 in. w.c. |
| Max Working Pressure | 150 PSI |
| Supply Voltage | 115V |
| Phase | Single Phase |
| Hertz | 60Hz |
| Gas Connection | 3/4" |
| Vent Connection | 2 " |
| Water Connection | 3/4" |
| DHW Connection | 1" |
| Installation Location | Indoor |
| Mount Type | Floor Mount, Wall Mount |
| Colour | Grey |
| Additional Specifications | Brand: Rinnai; Product Family: Solo Boiler (Heat-Only Model); Model: CH 90K BTU (IP090S); Fuel Type: Natural Gas or Liquid Propane Gas (LP) - Convertible with appropriate kit; Gas Supply Pressure:; - Natural Gas: Minimum 3.5 in. W.C. (0.87 kPa), Maximum 10.5 in. W.C. (2.61 kPa); - Propane Gas: Minimum 8.0 in. W.C. (1.99 kPa), Maximum 13.5 in. W.C. (3.36 kPa); Gas Consumption Range: 15,000 Btu/hr minimum to 90,000 Btu/hr maximum; Installation: Certified for installation in manufactured homes; Safety Features: Equipped with automatic ignition system; no pilot light required; Control Interface: PC Board with digital display for parameter settings and operation mode; Conversion Capability: Field convertible between Natural Gas and Propane using manufacturer’s conversion kit (includes conversion plate and manual); Combustion Analysis Port: Allows for professional combustion testing and adjustment; Compliance: CSA/ANSI certified, Energy Star qualified, meets CSA 4.9 standards; Installation Requirements: Must comply with local codes or National Fuel Gas Code ANSI Z223.1/NFPA 54 and CSA B149.1/B149.2 standards; High Altitude Installation: Includes procedure and labeling for Canadian installations between 2,000 ft and 4,500 ft elevation; Material: Stainless steel heat exchanger and durable boiler components (inferred from typical Rinnai construction standards); Dimensions & Mounting: Compact wall-mounted design with accessible front panel for maintenance and conversion (as shown in images); Warranty and Support: Backed by Rinnai America Corporation with technical support and service documentation available; Additional Features:; - Outdoor reset control compatible with multiple heating curves; - Hydraulic separation compatible for system integration; - Safety alert system with LED indicators on PC board; - Suitable for hydronic heating and domestic hot water applications in combination models (not solo) |
| Product Length/Depth | 11.5 " |
| Product Width | 18.5 " |
| Product Height | 30.11 " |
| Product Weight | 62.6 lb |
| Shipping Length/Depth | 14.6 " |
| Shipping Width | 20.9 " |
| Shipping Height | 33.5 " |
| Shipping Weight | 69.1 lb |
| Standby Heat Loss | 90000 Btu/h |