Settings shortcuts: General tips
Short, practical technician tips on settings shortcuts for general. Check each one against the manual for your exact model before acting.
Set the real time and CIP operation time
Navien · WEC600
Edit the clock or the CIP start time. The digital clock blinks when the setting mode is active. Editing order is hours, tens of minutes, ones of minutes. The clock returns to standby after 5 minutes without input.
- Press and hold Next for at least 3 seconds in normal operation, installation check or CIP mode.
- To set the clock, press OK to start, adjust with Next, and press OK to move between sections and confirm.
- To set CIP time, press Next once so the CIP logo blinks, then press OK and edit the same way.
- Press Back to go back a step or exit without saving at the hours setting.
Set time after power loss
Navien · WEC600
If power is lost for more than 30 minutes, the time must be set again. Note that the NDI modules flush every 24 hours even when the unit is powered off from the main panel.
- Long press Next to enter time setting.
- Use Next to increase the blinking value and OK to move to the next section.
- Press OK to confirm.
Rotary dial address setting
Viessmann · Versatronik 535 Solar gateway, RESOL controls
The rotary dial sets an address for sites with several gateways. With RESOL controls the dial needs no change and should stay at the factory default of 0.
- Leave the rotary dial at 0 for RESOL controls.
- Change the dial only if the site uses more than one gateway and an address is required.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.