Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Button combinations: General tips

Updated · by Aurora Star Tech Inc.

Short, practical technician tips on button combinations for general. Check each one against the manual for your exact model before acting.

Enter Installer Setting mode

Navien · WEC Series main panel

Press and hold Back and Next together for 3 seconds to open Installer Setting mode. STR mode is started from here.

  1. Press and hold the Back and Next buttons together for 3 seconds.
  2. Select STR mode from the installer menu (see 3.8, p. 38).

Enter STR mode from installer setting

Navien · WEC600

Holding Back and Next together starts installer setting mode, which is also where STR sterilization is started.

  1. Press and hold the Back and Next buttons together for 3 seconds.
  2. Enter STR mode from the installer setting menu.
  3. Refer to section 3.8 of the manual for the installer setting details.

Main panel button combinations

Navien · WEC600

Long presses are held for more than 3 seconds. Several combinations open service modes.

  1. Back + OK, long press: enter Install Check Mode.
  2. Back + Next, long press: enter Installer Setting Mode to view status info, run forced flushing, run forced CIP and reset errors.
  3. Back + OK + Next, long press: enter Reset Mode to reset the filter cartridge period and the CIP tank level.
  4. Back long press: skip initial regeneration and CIP mode steps.
  5. Next long press: set the time and the CIP operation time.
  6. OK long press: show feedwater TDS, product water TDS and cumulative treated water volume after CIP.
  7. Power long press: power the WEC on or off. When off, the internal bypass valve opens to pass feedwater.

Power the WEC off

Navien · WEC600

Puts the unit into Powering Off mode. Only the time stays on the display. Feedwater still reaches the home if water is used. The unit still flushes the NDI modules every 24 hours from last use, so do not cut power at the cord.

  1. Press and hold the Power button for 3 seconds.
  2. Do not unplug the power cord to shut the unit down.

Power the WEC on

Navien · WEC600

Powers the unit on from off mode. The ON indicator and user information appear on the display.

  1. Press and hold the Power button for 3 seconds.

Reset filter and CIP use period

Navien · WEC Series main panel

Resets the filter use period or CIP fill level after service. Press and hold Back, OK and Next together for 3 seconds.

  1. Press and hold the Back, OK and Next buttons together for 3 seconds.
  2. Confirm the reset on the display.

Activate access point mode

Viessmann · Vitoconnect OPTO2

Access point mode is used for Wi-Fi setup, licence access and router changes. It turns on automatically at first power-up and stays on until commissioning is complete.

  1. Press the operating button for longer than 5 seconds, but not longer than 30 seconds.
  2. Confirm the Wi-Fi LED is illuminated green.

Deactivate access point mode

Viessmann · Vitoconnect OPTO2

Access point mode turns off by itself after 5 minutes. It can also be turned off manually.

  1. Wait 5 minutes for automatic deactivation, or
  2. Press the operating button for longer than 5 seconds, but not longer than 30 seconds.
  3. Confirm the LED is no longer illuminated.

Re-enter configuration

Viessmann · Vitotrol 300A

To return to configuration, press the two buttons together for about 4 seconds. The button icons are not legible in the text extract, so confirm the buttons on the unit.

  1. Press the two buttons together and hold for about 4 seconds.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977