Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Navien Tankless Water Heater: E517 / E773 DIP switch and gas type on NHW700

Updated · by Aurora Star Tech Inc.

E517 / E773 DIP switch and gas type on NHW700 on a Navien tankless water heater: E517: the PCB DIP switches are set wrong (manual reset). E773: the heater thinks the gas connected does not match the gas type set at install (reset by parameter).

Homeowner with a tankless water heater problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NHW700-120SE/160SE/180SE/199SE, NHW700-160SU/180SU/199SU, NHW700-160AI/180AI/199AI, NHW700-160AE/180AE/199AE

Common causes of e517 / e773 dip switch and gas type on nhw700

  • Capacity DIP switches (DIP 2) do not match the model
  • Panel DIP 1-1 gas type set wrong
  • Wrong gas connected or manifold not changed during LP conversion
  • Measuring tolerance (E773 can show with the right gas)

How to fix e517 / e773 dip switch and gas type on nhw700: step by step

  1. Gas unit: only a qualified gas technician should work on it. Power off at the switch before unplugging any connector.
  2. E517: set the PCB DIP switches to match the model and reset. Still there: replace the PCB.
  3. E773: check what gas is connected. Panel DIP 1-1 ON = propane, OFF = natural gas.
  4. Check the manifold nozzle size matches the gas and look at the flame (right number of flames in each row). Check for gas leaks.
  5. The unit can only be converted with the Navien conversion kit.
  6. Gas and settings match but E773 stays: call Navien technical support.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Tankless Water Heater codes

Models

NHW700-120SENHW700-160AENHW700-160AINHW700-160SENHW700-160SUNHW700-180AENHW700-180AINHW700-180SENHW700-180SUNHW700-199AENHW700-199AINHW700-199SENHW700-199SU

Source: Navien NHW700 Non-Condensing Water Heater Service Manual (V1.0, Apr 2023), 7.3.16 p.111, 7.2 p.91, 5.12 p.82-84, 5.10 p.80, 3.3 p.24. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977