Navien Tankless Water Heater: E109 fan motor fault on NHW700
E109 fan motor fault on NHW700 on a Navien tankless water heater: The fan speed signal stays near 0 or too low. Shows after 3 seconds of low speed while firing.
Applies to: NHW700-120SE/160SE/180SE/199SE, NHW700-160SU/180SU/199SU, NHW700-160AI/180AI/199AI, NHW700-160AE/180AE/199AE
Common causes of e109 fan motor fault on nhw700
- Fan seized or loose
- No power to the fan
- Wet fan connector (from a leak)
- Loose fan plug at the PCB
- Failed fan motor
- PCB fault
How to fix e109 fan motor fault on nhw700: step by step
- Power off before unplugging connectors or measuring resistance.
- Spin the fan by hand. Will not turn: replace the fan motor.
- Check the fan plug at the fan and at the PCB. Wet plug: power off, dry everything, put it back.
- Power on and check the fan supply: red-black about 127-184 V DC (about 170 V), black-yellow 15 V DC. Speed control black-orange 0-7.5 V DC, speed pulse black-white.
- No supply voltage: check the plug, then the PCB.
- Supply good, fan slow: check the APS, cycle power fully. Code comes back: replace the fan motor.
- New fan and still there: replace the PCB.
If the unit shows an error code, look it up: Navien Tankless Water Heater codes
Models
NHW700-120SENHW700-160AENHW700-160AINHW700-160SENHW700-160SUNHW700-180AENHW700-180AINHW700-180SENHW700-180SUNHW700-199AENHW700-199AINHW700-199SENHW700-199SU
Source: Navien NHW700 Non-Condensing Water Heater Service Manual (V1.0, Apr 2023), 7.3.7 p.102-103, 5.2 p.71, 5.5 p.74. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.