Navien Tankless Water Heater: E012 flame loss on NHW700
E012 flame loss on NHW700 on a Navien tankless water heater: The flame went out while running. The heater shuts the gas, tries again and counts. After 20 flame losses in a row it shows E012 and locks out (manual reset).
Applies to: NHW700-120SE/160SE/180SE/199SE, NHW700-160SU/180SU/199SU, NHW700-160AI/180AI/199AI, NHW700-160AE/180AE/199AE
Common causes of e012 flame loss on nhw700
- Low gas pressure, mostly when other gas appliances run
- Gas meter or gas line too small, crushed packing or tape in a fitting
- Wrong DIP switch setting or low-stage gas pressure set wrong
- Dirty flame rod
- Cracked or shifted burner plate
- Blocked manifold (flame loss on stage 2)
- Gas valve, APS, ground or power problem
- PCB fault
How to fix e012 flame loss on nhw700: step by step
- Gas unit: only a qualified gas technician should work on it. Power off at the switch before unplugging any connector.
- Check inlet gas pressure static and while the heater and other appliances fire. Check the meter size and the gas connector.
- Check the DIP switches and the low-stage gas pressure adjustment.
- Clean or replace the flame rod.
- Look at the burner plate for cracks or shifting and check the flame rod gap.
- Loses flame on stage 2: check the manifold for blockage.
- Check the gas valve, APS, ground wire and supply voltage (97-138 V AC).
- Still there: replace the PCB.
If the unit shows an error code, look it up: Navien Tankless Water Heater codes
Models
NHW700-120SENHW700-160AENHW700-160AINHW700-160SENHW700-160SUNHW700-180AENHW700-180AINHW700-180SENHW700-180SUNHW700-199AENHW700-199AINHW700-199SENHW700-199SU
Source: Navien NHW700 Non-Condensing Water Heater Service Manual (V1.0, Apr 2023), 7.3.3 p.98, 7.2 p.90, 5.5 p.75. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.