Navien Tankless Water Heater: E004 false flame on NHW700

Updated · by Aurora Star Tech Inc.

E004 false flame on NHW700 on a Navien tankless water heater: Flame signal seen for 3 seconds before the burner should light, or for 3 seconds during post-purge after gas was shut off. The fan purges and the pump runs. Auto reset.

Homeowner with a tankless water heater problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NHW700-120SE/160SE/180SE/199SE, NHW700-160SU/180SU/199SU, NHW700-160AI/180AI/199AI, NHW700-160AE/180AE/199AE

Common causes of e004 false flame on nhw700

  • Gas valve leaking through (flame before or after a burn)
  • Spark jumping from electrode to flame rod
  • Gas pressure above range pushing the valve open
  • Bad ground or electrical noise
  • PCB fault

How to fix e004 false flame on nhw700: step by step

  1. Gas unit: only a qualified gas technician should work on it. Power off at the switch before unplugging any connector.
  2. Watch the burner with no call for heat. Flame there with no ignition: the gas valve is leaking, replace it.
  3. No real flame: it is electrical noise. Check the ground wire and the flame rod position. Clean or replace the flame rod.
  4. Check the spark is going to the burner, not to the flame rod.
  5. Check inlet gas pressure is not above range (natural gas max 10.5 in. WC, propane max 13 in. WC).
  6. Still there: replace the PCB.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Tankless Water Heater codes

Models

NHW700-120SENHW700-160AENHW700-160AINHW700-160SENHW700-160SUNHW700-180AENHW700-180AINHW700-180SENHW700-180SUNHW700-199AENHW700-199AINHW700-199SENHW700-199SU

Source: Navien NHW700 Non-Condensing Water Heater Service Manual (V1.0, Apr 2023), 7.3.2 p.97, 3.3.2 p.28. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.