Navien Tankless Water Heater: Cascade, panel and air handler codes on NHW700 (E438, E736, E740, E782, E785)

Updated · by Aurora Star Tech Inc.

Cascade, panel and air handler codes on NHW700 (E438, E736, E740, E782, E785) on a Navien tankless water heater: E438 = air handler (AHU) pump, E736 = cascade communication, E740 = AHU outdoor thermistor (sub 1 open, 2 short), E782 = main panel communication, E785 = AHU direct water flow switch. All alarms except E438 (manual reset).

Homeowner with a tankless water heater problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NHW700-120SE/160SE/180SE/199SE, NHW700-160SU/180SU/199SU, NHW700-160AI/180AI/199AI, NHW700-160AE/180AE/199AE

Common causes of cascade, panel and air handler codes on nhw700 (e438, e736, e740, e782, e785)

  • External pump not running
  • Cascade wiring fault
  • Outdoor sensor wiring or outdoor reset not set up
  • Front panel or panel cable fault
  • Flow switch wiring
  • PCB fault

How to fix cascade, panel and air handler codes on nhw700 (e438, e736, e740, e782, e785): step by step

  1. Power off before unplugging connectors or measuring resistance.
  2. E438: check the external circulation pump runs.
  3. E736: check the cascade wiring between units, then the PCB.
  4. E740: check the outdoor reset curve is set up, then the outdoor sensor wiring.
  5. E782: check the panel cable at both ends, then the panel, then the PCB.
  6. E785: check the flow switch wiring, then the PCB.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Tankless Water Heater codes

Models

NHW700-120SENHW700-160AENHW700-160AINHW700-160SENHW700-160SUNHW700-180AENHW700-180AINHW700-180SENHW700-180SUNHW700-199AENHW700-199AINHW700-199SENHW700-199SU

Source: Navien NHW700 Non-Condensing Water Heater Service Manual (V1.0, Apr 2023), 7.1 p.88-89, 7.2 p.91. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.