Lifebreath Hrv: Supply air feels cold
Supply air feels cold on a Lifebreath hrv: Fresh air coming in feels cold to the occupants in winter.
Applies to: Lifebreath RNC series HRV
Common causes of supply air feels cold
- Very cold outdoor temperature
- Furniture or closed doors stopping air from mixing
- Supply ducted into the furnace return with the furnace fan off
How to fix supply air feels cold: step by step
- Lower the HRV supply speed.
- Check that furniture and closed doors are not trapping the supply air in one spot.
- If the HRV supply goes into the furnace return, run the furnace fan on continuous so the air gets mixed and spread out.
If the unit shows an error code, look it up: Lifebreath Hrv codes
Models
Source: Lifebreath RNC5-ES Homeowner's Guide (69-RNC5-OWNERS 012616), Troubleshooting, p. 14. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.