Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Lifebreath Hrv: Bathroom timer does not bring HRV to high

Updated · by Aurora Star Tech Inc.

Bathroom timer does not bring HRV to high on a Lifebreath hrv: Pressing the 20/40/60 timer does nothing.

Homeowner with a heating or cooling system problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: 99-DET01, 99-DET02 timers, 99-RX02 repeater

Common causes of bathroom timer does not bring hrv to high

  • Main control mode set to OFF (timers don't work then unless wired for it)
  • Wireless 99-DET02 out of range (about 40 ft clear line)
  • Timer battery low
  • Repeater not linked
  • Timer in lockout (99-DET01)

How to fix bathroom timer does not bring hrv to high: step by step

  1. Check the main control is on and not set to OFF.
  2. On a wireless timer, check the red battery light and change the battery if lit.
  3. Check the distance to the main control. Add or move a 99-RX02 repeater if it is out of range.
  4. On a wired 99-DET01, hold the select button 5 seconds to take it out of lockout.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Lifebreath Hrv codes

Models

RNC5-ES

Source: Lifebreath RNC5-ES Homeowner's Guide (69-RNC5-OWNERS 012616), Timers, p. 9-11. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service