Viessmann Boiler: Wiring the room controller to Viessmann Vitodens 100-W, WB1B
Wiring the room controller to Viessmann Vitodens 100-W, WB1B on a Viessmann boiler: The OT communication wires go to the 6-pole terminal block harness. The outdoor sensor can be wired either to the boiler 6-pole connector or to terminals 5 and 6 on the controller. The OT wires are not polarity sensitive.
Applies to: Vitodens 100-W WB1B
How to fix wiring the room controller to viessmann vitodens 100-w, wb1b: step by step
- Refer to the boiler manual and remove the boiler cover.
- Find the wiring harness with the 6-pole terminal block.
- Find the wire marker for terminal 1.
- If the outdoor sensor is not yet installed, wire it to the 6-pole connector on the boiler or to terminals 5 and 6 on the controller.
- Connect the controller to terminals 1 and 2 of the 6-pole terminal block on the Vitodens 100-W WB1B.
- Terminate the OT wires at the controller sub-base on terminals 1 and 2.
If the unit shows an error code, look it up: Viessmann Boiler codes
Source: Versatronik COMO OT manual, p. 11. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.