Wiring the room controller to Viessmann Vitodens 100-W, WB1A on a Viessmann boiler: The 4-pole plug on the boiler control provides the connection. The OT communication wires go to terminals 1 and 2 on the controller sub-base and are not polarity sensitive. If the 4-pole plug is missing from the boiler, get a replacement from the boiler supplier.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Vitodens 100-W WB1A

How to fix wiring the room controller to viessmann vitodens 100-w, wb1a: step by step

  1. Turn the boiler control down as described in the boiler manual.
  2. Find the 4-pole plug in the upper left corner on the back of the control.
  3. Wire the field cable into the 4-terminal plug at terminals 3 and 4.
  4. Run the field wire from the boiler to the controller.
  5. Connect the two communication wires to terminals 1 and 2 on the controller sub-base.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Viessmann Boiler codes

Source: Versatronik COMO OT manual, p. 10. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.