Settings shortcuts: Wall Furnace tips
Short, practical technician tips on settings shortcuts for wall furnace. Check each one against the manual for your exact model before acting.
Select remote thermostat mode (01) or control panel mode (02)
Rinnai · Rinnai EX08DT, EX11DT, EX17DT, EX22DT direct vent wall furnaces
Control mode 00 is the factory default; 01 is for a wall thermostat kit (do not select without the connection parts); 02 returns to the furnace's own panel. Do not unplug the furnace within two hours of entering remote thermostat mode or it reverts to the factory default.
- Furnace plugged in but OFF, Set back feature OFF.
- Hold Economy + Up + Program for 2.5 seconds, then release: 00 shows.
- Press Up to move to 01 or 02.
- Press ON/OFF; the display goes blank and the mode is stored.
Select the gas code (gas type, altitude, vent length)
Rinnai · Rinnai EX08DT, EX11DT, EX17DT, EX22DT direct vent wall furnaces
A codes are natural gas, L codes are propane; digits 1 to 4 pick the altitude band.
- With the furnace off, hold the Test Switch on the PC board until it beeps.
- Pick the code with the up and down buttons.
- Press the Test Switch twice to store it; the display goes blank.
Switch the display between Fahrenheit and Celsius
Rinnai · Rinnai EX08DT, EX11DT, EX17DT, EX22DT direct vent wall furnaces
Factory default is Fahrenheit.
- Furnace must be off.
- Press Timer 1 and Timer 2 together for about 5 seconds: the display shows ºC or ºF.
- Use the arrow keys to select the scale.
- Press ON/OFF to store it.
Turn Set back (frost protection) on or off
Rinnai · Rinnai EX08DT, EX11DT, EX17DT, EX22DT direct vent wall furnaces
Set back starts heating whenever room temperature drops below the preset minimum (38 to 78 F, default 60 F); it is on from the factory.
- With the furnace OFF, press Set back (light comes on).
- Adjust the minimum temperature with the up/down buttons.
- Press Set back again to turn the feature off.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.