NTI Boiler: Summer/winter changeover operation

Updated · by Aurora Star Tech Inc.

Summer/winter changeover operation on a NTI boiler: With automatic changeover on, the boiler switches from winter to summer mode based on outdoor temperature. Factory switchover temperature is 68 F. If outdoor temperature stays more than 1 F above the switchover temperature for 5 h, the boiler goes to summer mode. If it stays more than 1 F below for 5 h, it returns to winter mode. In summer mode the boiler can turn heating off.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NTI TRX boilers with user menu 11 and 12 set

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: NTI Boiler codes

Models

TRX085TRX110CTRX150TRX199TRX199C

More other tips for boiler

Source: NTI TRX150 manual, p. 69. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.