NTI Boiler: Canadian vent installation requirements

Updated · by Aurora Star Tech Inc.

Canadian vent installation requirements on a NTI boiler: Additional requirements for Canadian installations.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Installations in Canada

How to fix canadian vent installation requirements: step by step

  1. Use a vent pipe system certified to ULC-S636.
  2. Keep the first 3 feet of vent pipe from the boiler flue outlet readily accessible for visual inspection.
  3. Do not mix components from other vent systems or unlisted pipe or fittings.
  4. Use double-wall or insulated intake pipe in cold climates to stop moisture condensing in the incoming air.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: NTI Boiler codes

Models

TRX085TRX110CTRX150TRX199TRX199C

More commissioning tips for boiler

Source: NTI TRX150 manual, p. 34. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.