Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Lennox Gas Fireplace: Sooting or flame too blue – Lennox Elite LDV

Updated · by Aurora Star Tech Inc.

Sooting or flame too blue - Lennox Elite LDV on a Lennox gas fireplace: Long orange flames with black tips and soot on the glass or near the vent cap, or flames that stay blue and see-through.

Homeowner with a gas fireplace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Elite Linear View LDV42N, LDV42P, LDV54N, LDV54P (SIT Proflame DFC control, remote wall receiver)

Common causes of sooting or flame too blue - lennox elite ldv

  • Air shutter closed too far (soot)
  • Air shutter open too far (blue flame)
  • Flames hitting the panels
  • Vent run with many offsets

How to fix sooting or flame too blue - lennox elite ldv: step by step

  1. Safety: air shutter adjustment by a qualified tech only. Glass door must be on and sealed. The lever and nearby surfaces are hot.
  2. Run the burner at least 30 minutes before judging. A new fire starts blue and turns yellow-orange.
  3. If sooting, first check the flames are not touching the panels and the media is placed right.
  4. Lever is on the lower right below the door (remove the surround for easier access). Push in = more air (more open). Pull out = less air.
  5. Sooting or orange flame: open the shutter a bit. Flame stays blue: close it a bit. Run a few minutes and check again.
  6. More offsets in the vent usually need a wider shutter opening. Propane flames that candle or look stringy also need more air.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Lennox Gas Fireplace codes

Models

LDV42NLDV42PLDV54NLDV54P

Source: Lennox Hearth Elite Linear View Direct-Vent Gas Fireplace LDV42/LDV54 Installation Instructions 506011-02 (06/2012), Adjusting the Air Shutter p.32. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977