Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Viessmann Error Code LH07: Speed limited by remote (Mini-Split)

Updated · by Aurora Star Tech Inc.

Viessmann error code LH07 on a mini-split means: Speed limited by remote. It is also called Viessmann diagnostic code LH07.

Low severityMini-SplitViessmann DLFSHB high wall indoor

Homeowner? What Viessmann code LH07 means for you

Usually minor Your ductless mini-split is reporting: Speed limited by remote. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the remote: fresh batteries and the right mode (Cool, Heat or Auto).
  • Check the breaker and the outdoor disconnect; both should be ON.
  • Open the front cover of the indoor unit and rinse the washable filters if they are dusty; let them dry before putting them back.
  • Keep the outdoor unit clear of snow, ice and leaves.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Viessmann error code LH07 mean?

Compressor frequency limited by the remote controller setting.

Applies to: DLFSHBH high wall indoor units 09-24K (Midea / Carrier / Viessmann) on DLC multi-zone or single-zone outdoor units

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Viessmann models that use code LH07

DLFSHBH09XAKDLFSHBH12XAJDLFSHBH12XAKDLFSHBH18XAKDLFSHBH24XAK

Other Viessmann Mini-Split codes

CodeMeaning
LC01Speed limited by condenser temperature
LC02Speed limited by discharge temperature
LC03Speed limited by current
LC05Speed limited by voltage
LC06IPM high temperature / PFC frequency limit
LH00Speed limited by indoor coil temperature
LLControls locked
nANo fault
nFFilter replacement reminder
ODU --Outdoor board standby
ODU 00Wiring / piping check finished
ODU CEAutomatic wiring / piping check running

All Viessmann Mini-Split error codes →

Viessmann code LH07: homeowner questions

What does Viessmann code LH07 mean?

Speed limited by remote. Compressor frequency limited by the remote controller setting.

Is it safe to keep using my ductless mini-split with code LH07?

Usually yes. Code LH07 is normally minor, but if it keeps coming back have it checked.

Can I reset Viessmann code LH07 myself?

You can try one reset (power off for 30 seconds, then on). If Viessmann code LH07 comes back, the cause is still there and a licensed technician should check it.

Who can fix Viessmann code LH07 near me?

Aurora Star Tech Inc. repairs Viessmann ductless mini-splits in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Carrier MS-DLFSHB-01 High Wall Ductless Service Manual (04/2021), Table 9 p.17. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service