Bosch Heat Pump: Start a manual defrost test (hold FORCE 6 s)

Updated · by Aurora Star Tech Inc.

Start a manual defrost test (hold FORCE 6 s) on a Bosch heat pump: Holding FORCE for 6 seconds starts a forced defrost test. The unit must be in a heating call and have run 8 minutes or more. Defrost starts after about 40 seconds and the display shows dF.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: BOVA IDS 2.0, IDS Premium Connected and IDS Light heat pumps

How to fix start a manual defrost test (hold force 6 s): step by step

  1. Make sure there is a heat call and the unit has run 8 minutes or more
  2. Press and hold the FORCE button for 6 seconds
  3. Wait about 40 seconds; the display shows dF
  4. For a second test wait 5 minutes and repeat
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Bosch Heat Pump codes

Models

Bosch IDS 2.0

BOVA-36HDN1-M20GBOVA-60HDN1-M20G

Bosch IDS Light

BOVA15-24BOVA15-36BOVA15-60

Bosch IDS Premium Connected

BOVA36-20BOVA60-20

Source: Bosch IDS Premium Connected BTC 762003301 D (02.2025), 18.4 Defrost Description p.46; IDS Light BTC 762003308 D, Manual Defrost; IDS 2.0 service Rev3, 10.2.1 p.31. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977